Unsupervised Correction of Respiratory-induced Motion in 4D Short-axis Cardiac Cine MRI

Mikkel B. Stegmann, Dorthe Pedersen, Henrik B. W. Larsson

AbstractPurpose: To rapidly and automatically correct for respiratory-induced motion in dynamic three-dimensional cardiac magnetic resonance images acquired using breath-hold.

Methods: Statistical models are employed to localise the left ventricle in a set of short-axis images. Subsequently, translation estimates are derived and employed for correction of respiratory motion.

Results: Qualitatively and quantitatively validation was carried out on 12 subjects. Slice displacements were significantly reduced (p<0.001). Mean slice displacement before and after correction: 3.40+/-1.44 mm and 1.60+/-0.34 mm. Estimation and correction took <10 seconds per subject.

Conclusion: The presented method provides unsupervised, rapid and purely image-based correction of respiratory-induced motion in short-axis cardiac MRI.
TypeJournal paper [Submitted]
JournalJournal of Cardiovascular Magnetic Resonance (submitted)
Year2006    Month March
PublisherTaylor & Francis
BibTeX data [bibtex]
IMM Group(s)Image Analysis & Computer Graphics